In the suburbs of Aix-en-Provence, we have just installed our 93rd Bar Screen in the Bouches-du-Rhône.
With no Bar Screen in the plant's inlet pumping station, the pumps regularly clogged and the downstream fine screen became overloaded.
Our solution was to place the Bar Screen upstream of the pumps, fixed against the vertical wall of the station, facing the effluent inlet pipe.
The screenings are conveyed by a screw conveyor into a nearby skip.
The assembly is controlled by the standard FB electrical panel, mounted on one side of the Bar Screen.
Technical data
Supply of a automatic Bar Screen
- Type NG21
- ALL 316L STAINLESS STEEL
- Design flow 200 m3/h
- Bar spacing 25 mm
- Depth below mounting level 2100 mm
- Frame in two sections
Supply of a Screw Conveyor
- Type VTP200
- ALL 316L STAINLESS STEEL
- Length 3000 mm
- Discharge height 1850 mm
Project photos